Motorola PM400 Service Manual Page 39

  • Download
  • Add to my manuals
  • Print
  • Page
    / 350
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 38
3-2 TROUBLESHOOTING CHARTS
1.2 Button/Tones Select Error (Page 1 of 2)
No
Check Voltage Levels on
TP401 (Keypad Col)
and TP402 (Keypad Row)
(see table on next page)
Right
Voltage
Up Key
No
Check R846, R811
on Control Head
Right
Voltage
on Down Key
?
Check Control Head
connectivity continuity
and R429, R430, D401
(main board)
Connect DTMF Mic
to TELCO Connector
YES
Button/Tones Check
Check R845, R810
on Control Head
Right
Voltage
on P1/P2
Keys ?
Is there
0.75 Vdc on
MIC_SENSE
R429, on radio
Check R813, R814
on Control Head
?
A
YES
No
YES
No
Page view 38