VP ONCORE COMMAND REFERENCE
GMT CORRECTION (@@Ab)
Motorola Binary Format
Input Command Query Current GMT Offset:
@@Ab
xxxC<CR><LF>
xxx - $ffffff (three bytes, all hex $ff)
C – checksum
Message length: 10 bytes
Change current GMT Offset:
@@Ab
shmC<CR><LF>
s - sign 00 = positive
ff = negative
h - hours 0 .. 23
m - minutes 0 .. 59
C - checksum
Message length: 10 bytes
Response Message (To either command):
@@AbshmC<CR><LF>
s - sign 00 = positive
ff = negative
h - hours 0 .. 23
m - minutes 0 .. 59
C - checksum
Message length: 10 bytes