Motorola PTP 500 User Manual Page 15

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 14
The correct operation is as follows
1. Connect the RJ45 to the PIDU Plus and apply power to the PIDU Plus, the green
power LED should illuminate continuously.
2. 30 seconds after powering, the orange Ethernet LED should be observed starting
with 10 slow flashes.
3. If there is a local network connection plus traffic the Ethernet LED will light solidly
and flicker to show Ethernet activity.
If the system does not operate correctly, refer to the fault finding guide below.
Fault Finding Guide
The PIDU green power LED does not illuminate
Unplug the ODU connection from the PIDU and check the power LED illumination. If the
power LED still does not light then check the power source.
The PIDU green power LED flashes
A flashing power LED indicates that there is a short circuit on the output of the PIDU. Check
that pins 4&5 and 7&8 are not crossed with pins 1&2 and 3&6 on the RJ45, and check also
that there is a resistance greater than 100K ohms between pins 1&8.
The PIDU Ethernet orange LED flashes ten times but irregularly
Irregularly flashing, seen as a short gap followed by a long gap, indicates that the ODU has
booted in recovery mode. This can also indicate an installation wiring problem.
The PIDU Ethernet orange LED flashes ten times but does not show Ethernet activity
Failure of the Ethernet LED to show Ethernet activity can be due to wiring to pins 1&2 and
3&6 being incorrect, for example if the wiring to pins 1 and 3 are crossed.
15
Post-Power Testing and Fault Finding
Page view 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20

Comments to this Manuals

No comments